Damien BONNARD




Senior Teacher/Researcher

Phone : 33(0)5 57 82 02 47
Send an email



Cursus:
MCU-PH Chirurgie ORL otologie, CHU de Bordeaux
PhD Sciences Cognitives, Université de Bordeaux (2016)

Expertise: Système auditif, Thérapie intra-cochléaire, Chirurgie implants auditifs





27 publication(s) since Avril 2012:


Sort by

12/2018 | j int adv otol
Middle Ear Osteoma Causing Mixed Hearing Loss: A Case Report.
Molher J, Pujol EMD, Zounon ADS, Darrouzet V, Bonnard D
doi: 10.5152/iao.2018.5265

Abstract:
Osteomas of the middle ear are rare benign tumors. Their consequences and symptoms are due to their specific location, such as the promontory or the epitympanum and their contact with the facial nerve, the semicircular canal, the ossicles, and the oval or round windows. We report a very unusual case of middle ear osteoma (MEO) in a 23-year-old male patient causing a right mixed hearing loss by contacting and overwhelming the incus and stapes. The lesion was also closely attached to the tympanic portion of the fallopian canal. Since the stapes was not clearly visible behind the lesion, careful observation was preferred to surgery owing to the high risk of inner ear damage and facial palsy with removal of the lesion. MEOs are rarely situated at this critical site. Regular clinical and computerized tomography monitoring is warranted to check their growth. This case also supports the etiological theory of chronic middle ear inflammation causing osteomas.




10/2018 | acta otorhinolaryngol ital
Cochlear implantation in far-advanced otosclerosis: hearing results and complications.
Dumas AR, Schwalje AT, Franco-Vidal V, Bébéar JP, Darrouzet V, Bonnard D

Abstract:
Severe forms of otosclerosis known as far-advanced otosclerosis (FAO) can lead to severe to profound sensorineural hearing loss and can justify cochlear implantation. Because of the pathophysiology of otosclerosis, patients implanted for FAO may experience an increased rate of complications, such as facial nerve stimulation or electrode dislocation, and may have poorer hearing outcomes than expected. This retrospective study aimed to compare cochlear implantation hearing outcomes, surgical difficulties and complications in FAO patients versus non-FAO patients. Moreover, we evaluated whether high resolution computed tomography (CT scan) findings were predictive of perioperative problems, complications and hearing outcomes. FAO patients were diagnosed based on medical history, examination and CT scan. Thirty-five ears from FAO patients were compared to 38 control ears. Audiometric results were assessed at least 12 months after implantation by pure tone average, speech reception threshold, monosyllabic and disyllabic word recognition score (WRS) and Central Institute for the Deaf (CID) sentences test. Complications and surgical difficulties were compiled. CT scan findings were categorised within 3 grades of otosclerotic extension. No significant difference was found between FAO and non-FAO hearing outcomes, except that monosyllabic WRS were lower for FAO patients, especially those who underwent previous stapedotomy. Facial nerve symptomatology occurred in 8.6% of FAO patients; among these, one required explantation-reimplantation surgery. 86% of FAO implanted patients had retrofenestral extension on CT. These were associated with poorer disyllabic WRS (51% vs 68%, p < 0.05) than those with only fenestral involvement. Although not significant, high grade of severity on CT tended to be associated with surgical difficulties and complications. Cochlear implantation in FAO patients is an effective treatment technique. Though the overall complication rate is low, it tends to be higher in cases of severe extension on CT. Patient counselling should be adjusted accordingly.




Abstract:
BACKGROUND: Pitch perception of complex tones relies on place or temporal fine structure-based mechanisms from resolved harmonics and the temporal envelope of unresolved harmonics. Combining this information is essential for speech-in-noise performance, as it allows segregation of a target speaker from background noise. In hybrid cochlear implant (H-CI) users, low frequency acoustic hearing should provide pitch from resolved harmonics while high frequency electric hearing should provide temporal envelope pitch from unresolved harmonics. How the acoustic and electric auditory inputs interact for H-CI users is largely unknown. Harmonicity and inharmonicity are emergent features of sound in which overtones are concordant or discordant with the fundamental frequency. We hypothesized that some H-CI users would be able to integrate acoustic and electric information for complex tone pitch perception, and that this ability would be correlated with speech-in-noise performance. In this study, we used perception of inharmonicity to demonstrate this integration. METHODS: Fifteen H-CI users with only acoustic hearing below 500 Hz, only electric hearing above 2 kHz, and more than 6 months CI experience, along with eighteen normal hearing (NH) controls, were presented with harmonic and inharmonic sounds. The stimulus was created with a low frequency component, corresponding with the H-CI user's acoustic hearing (fundamental frequency between 125 and 174 Hz), and a high frequency component, corresponding with electric hearing. Subjects were asked to identify the more inharmonic sound, which requires the perceptual integration of the low and high components. Speech-in-noise performance was tested in both groups using the California Consonant Test (CCT), and perception of Consonant-Nucleus-Consonant (CNC) words in quiet and AzBio sentences in noise were tested for the H-CI users. RESULTS: Eight of the H-CI subjects (53%), and all of the NH subjects, scored significantly above chance level for at least one subset of the inharmonicity detection task. Inharmonicity detection ability, but not age or pure tone average, predicted speech scores in a linear model. These results were significantly correlated with speech scores in both quiet and noise for H-CI users, but not with speech in noise performance for NH listeners. Musical experience predicted inharmonicity detection ability, but did not predict speech performance. CONCLUSIONS: We demonstrate integration of acoustic and electric information in H-CI users for complex pitch sensation. The correlation with speech scores in H-CI users might be associated with the ability to segregate a target speaker from background noise using the speaker's fundamental frequency.




08/2018 | j am geriatr soc
Long-Term Cognitive Prognosis of Profoundly Deaf Older Adults After Hearing Rehabilitation Using Cochlear Implants.
Mosnier I, Vanier A, Bonnard D, Lina-Granade G, Truy E, Bordure P, Godey B, Marx M, Lescanne E, Venail F, Poncet C, Sterkers O, Belmin J
doi: 10.1111/jgs.15445

Abstract:
OBJECTIVES: To analyze long-term cognitive status and function after cochlear implantation in profoundly deaf individuals. DESIGN: Prospective observational longitudinal study. SETTING: Ten academic medical centers referent for cochlear implantation. PARTICIPANTS: Individuals aged 65 and older who qualified for cochlear implantation (N=70). MEASUREMENTS: Cognitive tests were administered before cochlear implantation and 1 and 5 or more years after cochlear implantation. Evaluation consisted of 6 tests assessing attention, memory, orientation, executive function, mental flexibility, and fluency. Cognitive status was determined as normal, mild cognitive impairment (MCI), or dementia. Speech perception in quiet and noisy conditions was assessed using disyllabic words, and quality of life was assessed using the Nijmegen Cochlear Implant Questionnaire. RESULTS: Mean follow-up was 6.8 years (range 5.5-8.5 years). Speech perception scores and quality of life remained stable from 1 to 7 years after cochlear implantation. Of 31 participants (45%) with MCI before cochlear implantation, 2 (6%) developed dementia during follow-up, 19 (61%) remained stable, and 10 (32%) returned to normal cognition. None of the 38 with normal cognition developed dementia during follow-up, although 12 (32%) developed MCI. CONCLUSION: MCI is highly prevalent in older adults with profound hearing loss. Nevertheless, we observed a low rate of progression to dementia, and cognitive function improved in some individuals with MCI at baseline. These results highlight that cochlear implantation should be strongly considered in profoundly deaf individuals, even those with MCI, who may have a specific subtype of MCI, with a possible positive effect of hearing rehabilitation on neurocognitive functioning.




Abstract:
We report the first case of a transtympanic iatrogenic internal carotid artery (ICA) pseudoaneurysm diagnosed in a 4-year-old child following a myringotomy. An endovascular treatment with a covered-stent was decided; spontaneous thrombosis was found during the therapeutic arteriography, and the procedure was aborted. Otoscopy and computed tomography (CT) scan monitoring showed a prolonged thrombosis and the disappearance of the pseudoaneurysm 18months after the diagnostic arteriography. Based on literature review, endovascular techniques seem to be preferred to the surgical approach for treatment of intrapetrous ICA pseudoaneurysm, however clinical and CT scan monitoring may also be a valid option.




06/2017 | clin otolaryngol
Iatrogenic facial nerve injuries during chronic otitis media surgery: a multicentre retrospective study.
Linder T, Mulazimoglu S, El Hadi T, Darrouzet V, Ayache D, Somers T, Schmerber S, Vincent C, Mondain M, Lescanne E, Bonnard D

Abstract:
OBJECTIVES: To give an insight into why, when and where iatrogenic facial nerve (FN) injuries may occur and to explain how to deal with them in an emergency setting. DESIGN AND SETTING: Multicentre retrospective study in eight tertiary referral hospitals over 17 years. PARTICIPANTS: Twenty patients with partial or total FN injury during surgery for chronic otitis media (COM) were revised. MAIN OUTCOME MEASURES: Indication and type of surgery, experience of the surgeon, intra- and postoperative findings, value of CT scanning, patient management and final FN outcome were recorded. RESULTS: In 12 cases, the nerve was completely transected, but the surgeon was unaware in 11 cases. A minority of cases occurred in academic teaching hospitals. Tympanic segment, second genu and proximal mastoid segments were the sites involved during injury. The FN was not deliberately identified in 18 patients at the time of injury, and nerve monitoring was only applied in one patient. Before revision surgery, CT scanning correctly identified the lesion site in 11 of 12 cases and depicted additional lesions such as damage to the lateral semicircular canal. A greater auricular nerve graft was interposed in 10 cases of total transection and in one partially lesioned nerve: seven of them resulted in an HB III functional outcome. In two of the transected nerves, rerouting and direct end-to-end anastomosis was applied. A simple FN decompression was used in four cases of superficially traumatised nerves. CONCLUSIONS: We suggest checklists for preoperative, intraoperative and postoperative management to prevent and treat iatrogenic FN injury during COM surgery.




04/2017 | clin otolaryngol
Arachnoid cyst of the fallopian canal and geniculate ganglion area: our experience of 9 cases.
Sagardoy T, de Mones E, Bonnard D, Darrouzet V, Franco-Vidal V

Abstract:





09/2016 | otolaryngol head neck surg
The Role of Electrode Placement in Bilateral Simultaneously Cochlear-Implanted Adult Patients.
De Seta D, Nguyen Y, Bonnard D, Ferrary E, Godey B, Bakhos D, Mondain M, Deguine O, Sterkers O, Bernardeschi D, Mosnier I

Abstract:
OBJECTIVE: To evaluate the influence of the electrode placement on hearing performance in adult patients who were simultaneously and bilaterally cochlear implanted. STUDY DESIGN: Case series with planned data collection. SETTING: Tertiary referral university centers. SUBJECTS AND METHODS: The postoperative computed tomography scan was studied for 19 patients who were simultaneously and bilaterally implanted with a long straight electrode array. The size of the cochlea was measured in consideration of the major cochlear diameter and cochlear height. The electrode-to-modiolus distance for the electrodes positioned at 180 and 360 degrees and the angular depth of insertion of the array were also measured. Speech perception was assessed at 1 and 5 years postimplantation with disyllabic word lists in quiet and in noise, with the speech coming from the front and a background noise (cocktail party) coming from 5 loudspeakers. RESULTS: At 1 year postimplantation, the electrode-to-modiolus distance at 180 degrees was correlated with the speech perception scores in both quiet and noise. In patients with a full electrode insertion, no correlation was found between the angular depth of insertion and hearing performance. The speech perception scores in noise gradually declined as a function of the number of inserted and active electrodes. No relationship between electrode position and speech perception scores was found at 5 years postimplantation. CONCLUSION: In adult patients who were simultaneously and bilaterally implanted, the use of a long straight array, the full electrode array insertion, and the proximity to the modiolus might be determining factors to obtain the best speech performance at 1 year, without influence on the speech perception scores after long-term use.




Abstract:
The objective of this study is to report the surgical outcome after middle fossa approach (MFA) plugging in patients suffering from a superior semi-circular canal dehiscence (SCD) syndrome. This is a retrospective case review. Tertiary referral center. Sixteen ears in 13 patients with a SCD syndrome suffering from severe and disabling vestibular symptoms with a bony dehiscence on CT scan >3 mm and decreased threshold of cervical vestibular evoked potentials (cVEMPs). We assessed preoperatively: clinical symptoms, hearing, cVEMPs threshold, size of dehiscence and videonystagmography (VNG) with caloric and 100 Hz vibratory tests. Postoperatively, we noted occurrences of neurosurgical complication, evolution of audiological and vestibular symptoms, and evaluation of cVEMP data. Tullio's phenomenon was observed in 13 cases (81.3 %) and subjectively reported hearing loss in seven (43.7 %). All patients were so disabled that they had to stop working. No neurosurgical complications were observed in the postoperative course. In three cases (16.6 %), an ipsilateral and transitory immediate postoperative vestibular deficit associated with a sensorineural hearing loss (SNHL) was noted, which totally resolved with steroids and bed rest. All patients were relieved of audiological and vestibular symptoms and could return to normal activity with a mean follow-up of 31.1 months (range 3-95). No patient had residual SNHL. cVEMPs were performed in 14 ears postoperatively and were normalized in 12 (85.7 %). Two of the three patients operated on both sides kept some degree of unsteadiness and oscillopsia. MFA plugging of the superior semi-circular canal is an efficient and non-hearing deteriorating procedure.




03/2016 | hear res
Harmonic fusion and pitch affinity: Is there a direct link?
Bonnard D, Dauman R, Semal C, Demany L
doi: 10.1016/j.heares.2015.08.015

Abstract:
Simultaneous pure tones approximately one octave apart tend to be fused perceptually and to evoke a single pitch sensation. Besides, sequentially presented pure tones show a subjective 'affinity' or similarity in pitch when their frequency ratio is close to one octave. The aim of the study reported here was to determine if these two perceptual phenomena are directly related. Each stimulus was a triplet of simultaneous or successive pure tones forming frequency ratios varying across stimuli between 0.96 and 1.04 octaves. The tones were presented at a low sensation level (15 dB) within broadband threshold-equalizing noise, in order to prevent them from interacting in the cochlea when they were simultaneous. A large set of stimulus comparisons made by 18 listeners indicated that: (1) when the tones were simultaneous, maximal fusion was obtained for a mean frequency ratio deviating by less than 0.2% from one octave, and fusion decreased less rapidly above this frequency ratio than below it; (2) when the tones were presented successively, maximal pitch affinity was obtained for a mean frequency ratio significantly larger than one octave, and pitch affinity decreased more rapidly above this frequency ratio than below it. The differences between the results obtained for simultaneous and successive tones suggest that harmonic fusion and pitch affinity are unrelated phenomena.